Difference between revisions of "LoraWanDustSensor"

From RevSpace
Jump to navigation Jump to search
m (The concept)
m (Node design)
Line 213: Line 213:
  
 
The luftdaten backend has a 5 minute "heartbeat", so at least one measurement per 5 minutes should be sent to avoid disappearing from the map.
 
The luftdaten backend has a 5 minute "heartbeat", so at least one measurement per 5 minutes should be sent to avoid disappearing from the map.
The node firmware (attempts to) send a message every 145 seconds, just like the luftdaten WiFi sensor.
+
The node firmware (attempts to) send a message every 4m30s seconds, just like the luftdaten WiFi sensor.
 +
A little bit of randomness (30 s) is added to avoid nodes transmitting at exactly the same time over long periods of time and interfering with each other.
  
 
Measurements run in a cycle running through the following states:
 
Measurements run in a cycle running through the following states:

Revision as of 13:54, 24 November 2020

Project LoRaWAN dust Sensor
LoraWanDustSensor.jpg
LoRaWAN airborne particulate matter sensor
Status In progress
Contact bertrik
Last Update 2020-11-24

The concept

The concept consists of:

  • a sensor that measures airborne particulate matter and sends the measurement data using LoRa to TheThingsNetwork.
  • a forwarder application that collects the data from TTN and forwards it to luftdaten.info, opensensemap, mycayenne dashboard, etc.

This has been done before by other people, but it appears there is no universal solution. I am publishing all source code on github and will put up documentation on this wiki. This concept uses Cayenne because it is the closest practical thing towards a universal format but still reasonably compact format.

A similar thing has been done by:

One thing in particular that my concept does better than existing solutions is to use proper OTAA for the LoRa connection to TTN. OTAA means over-the-air-activation and is a mechanism to dynamically negotiate encryption keys and communication settings.

The OTAA key is hardcoded into the node, the session keys are not. The node identifies itself by its built-in unique ESP32 serial number.

This makes it possible to have a *single* firmware image for all sensor nodes and it simplifies the setup:

  • each node can be flashed with the same firmware
  • the node shows its unique Device EUI on the OLED
  • at the TTN console, you register the node with the unique Device EUI
  • the sensor node receives encryption keys over the air automatically by OTAA
  • done!

(idea: an ESP32 has a wifi connection too, perhaps registering the node can be done fully automatically, over wifi/internet)

Next steps

  • implement the ESP-Now lamp/display protocol, see https://revspace.nl/StofAnanas#Next_generation
  • update TTN upload schedule, set interval to luftdaten interval of 5 minutes, add some upload time randomness and avoid synchronised collisions between nodes
  • disable screen when idle, to avoid burn-in of the OLED?
  • internal web server, for configuration, information?
  • firmware update over WiFi

Links

Useful links for the TTGO LoRa board:

Hardware

The node is based on the Arduino framework:

  • for the processor board, either the TTGO ESP32 board ("ttgo-lora32-v1") and the Heltec LoRa32 V2 can be used.
  • the particulate matter sensor is the SDS-011, just like in the luftdaten project.
  • the humidity/temperature sensor is the BME280 (superior to the DHT11/22).

TODO: plaatjes van de hardware

Pinout

TTGO LoRa v1 Heltec LoRa v2 Sensor Remark
5V 5V SDS011 5V (pin 3) triple-check this, swapping 5V/GND destroys the SDS011
GND GND SDS011 GND (pin 5) triple-check this, swapping 5V/GND destroys the SDS011
GPIO23 GPIO23 SDS011 RXD (pin 6) (was GPIO25)
GPIO22 GPIO22 SDS011 TXD (pin 7) (was GPIO35)
3.3V 3.3V/Vext BME280 3V Both Vext and 3.3V can be used
GND GND BME280 GND ground
GPIO15 GPIO15 BME280 SCL data
GPIO4 GPIO4 BME280 SDA data

For reference:

TTGO LoRa v1

Technical documents:

Heltec LoRa32 v2

Technical documents:

Software

Compile and upload the firmware

Source code is hosted on github:

  • Arduino node, written in C/Arduino, built using platformio. This firmware joins TTN by OTAA and sends the measurement data using Cayenne.
  • TTN-to-luftdaten forwarder, written in Java, built using gradle. This picks up the Cayenne encoded data and forwards it to the Luftdaten API.

On Linux, with platformio (the command line tool), instructions for Debian Linux are:

  • install platformio:
 sudo apt install python3-pip
 sudo pip3 install platformio
 pio update
  • get the source from github:
 git clone https://github.com/bertrik/LoraWanPmSensor
  • enter the correct directory:
 cd LoraWanPmSensor
 cd Esp32PmSensor
  • compile and upload (for TTGO LoRa32 v1 board):
 pio run -e ttgov1 -t upload
  • compile and upload (for Heltec LoRa32 v2 board):
 pio run -e heltecv2 -t upload

On Windows, with the Arduino IDE

  • Install the Arduino IDE ...
  • Get the ESP32 support package ...
  • Install the following libraries
    • ESP8266_SSD1306
    • MCCI LoRaWAN LMIC library, version 3.2.0
    • SparkFun BME280
  • Set the target to either the TTGO LoRa32 v1 or Heltec LoRa32 v2
  • Ctrl-U to compile and upload

Payload encoding

Cayenne

It's reasonably compact, it's a standard format, you can get a preview of the data in the TTN console. Interacts nicely with other platforms.

Specification for Cayenne LPP 2.0

Over-the-air payload encoding:

  • PM1.0: digital input (type 2), channel id 0, with value in units of 0.01 ug/m3, saturated to 327.67 ug/m3 (optional)
  • PM10: digital input (type 2), channel id 1, with value in units of 0.01 ug/m3, saturated to 327.67 ug/m3
  • PM2.5: digital input (type 2), channel id 2, with value in units of 0.01 ug/m3, saturated to 327.67 ug/m3
  • Temperature: temperature (type 103), with value in units of 0.1 degrees celcius
  • Humidity: humidity (type 104), with value in units of 0.5 %
  • Pressure: barometer (type 115), with value in units of 0.1 mbar, or 10 Pa (optional)

Dust values higher than 327.67 are encoded as 327.67, this is the maximum that can be represented as analog value in Cayenne. A nice thing about Cayenne is that you can simply leave items out if you don't support them, which results in a shorter yet still valid message.

Example:

 0x01 0x01 0xXX 0xXX  0x02 0x01 0xYY 0xYY  0x03 0x67 0xTT 0xTT  0x04 0x68 0xHH
 <== PM10 value ===>  <== PM2.5 value ==>  <== temperature ==>  <= humidity =>

Total payload size is 15 bytes. The LoRaWAN header adds 13 bytes (at least).

Particulate matter values encoded are averaged over the measurement interval.

Update: discovered that the Cayenne standard *does* actually support a "particle concentration" id, this is 125, derived from IPSO id 3325 http://www.openmobilealliance.org/tech/profiles/lwm2m/3325.xml . No idea yet though how to specify the type of particle measurement, if there's any convention for PM10, PM2.5, etc. The resolution is only 1 ppm, with typical sensors delivering 0.1 ppm resolution.

Binary

How other projects encode the data:

A smaller payload means less time in the air, smaller chance of collision with other LoRaWAN packets and more packets per hour. However, there is always an overhead from the LoRaWAN package (minimum 13 bytes), so using the smallest encoding (5 bytes) compared to the largest (16 bytes), reduces the on-air-time by only 23%.

LoraWan time budget

Consider the following:

  • radio regulations generally have a 1% duty cycle requirement for the two bands used by the 8 LoRaWAN (EU) frequencies, so according to the legal limits, there is about 86400x0.01x2 = 1728 seconds per day send time at the best case.
  • TheThingsNetwork has a FUP of 30s of data upload per day, actually a huge restriction compared to the send time allowed purely by radio regulations.
  • The Luftdaten backend appears to run on a 5 minute interval, or 288 measurements per day.
  • The default Luftdaten firmware sends new data every 145s by default

With the TTN FUP of 30s upload per day, we can spend 30s / 288 = 104 ms on each transmission.

Using the LoRaWAN airtime calculator we can determine which modes can be used. At 15 bytes payload, this is only possible at SF7, the highest LoRa speed. Stretching the TTN guideline a bit, say by a factor 2, we can achieve those transfers still only at SF7 and SF8. So you need to be relatively close to a gateway.

With a smaller payload, can we use higher spreading factors? :

  • skip T/RH/P completely (8 bytes left): SF7 is possible, at SF8 we spend 102 ms per transmission
  • skip P only (15 bytes left): SF7 is possible, at SF8 we spend 123 ms per transmission

So, in conclusion: With the FUP of TTN and use of Cayenne encoding, you can just barely send enough data to transport Luftdaten PM data!

Node design

Source code for the particulate matter measurement node can be found on the github page.

The luftdaten backend has a 5 minute "heartbeat", so at least one measurement per 5 minutes should be sent to avoid disappearing from the map. The node firmware (attempts to) send a message every 4m30s seconds, just like the luftdaten WiFi sensor. A little bit of randomness (30 s) is added to avoid nodes transmitting at exactly the same time over long periods of time and interfering with each other.

Measurements run in a cycle running through the following states:

  • INIT: determine presence of the SDS011, print the SDS011 serial number
  • IDLE: wait until the start of the cycle, then turn on the fan
  • WARMUP: wait 20 seconds while the sensor "warms up"
  • MEASURE: measure 10 seconds, then turn off fan, calculate median/average and send LoRaWAN message

Building with platformio

Platformio is used to compile and upload the code to the node.

To install platformio (example for Debian):

 sudo apt install python3-pip
 sudo pip3 install platformio
 pio update

To compile and upload:

 pio run -t upload

TTN key provisioning

The node needs to be registered at TheThingsNetwork, in order for its messages to be accepted by the TTN.

The following scheme is used to make TTN provisioning as simple as possible:

  • Each node can be programmed with the *same* software, no source code modification is required
  • The node administrator needs to enter the following properties at the TTN console, for each node:
    • The Device EUI is derived from the node-specific ESP32 MAC address, the node shows this on its OLED
    • The App EUI has a fixed value and is the same for all nodes
    • The App Key has a fixed value and is the same for all nodes
    • Use 32-bit frame counter, leave frame counter checks enabled
    • A long press on the PRG button restarts the OTAA procedure

Backend

This is implemented by my LoraLuftdatenForwarder.

It currently supports the following:

  • subscribe to a TTN MQTT stream and receive incoming messages
  • decode Cayenne and custom payloads
  • forward to luftdaten.info/sensor.community
  • forward to opensensemap.org
  • forward to feinstaub app (experimental), https://pm.mrgames-server.de/

Development

To receive data using mosquitto, separately from the backend:

 mosquitto_sub -h eu.thethings.network -p 1883 -t +/devices/+/up -u particulatematter -P ttn-account-v2.cNaB2zO-nRiXaCUYmSAugzm-BaG_ZSHbEc5KgHNQFsk

Example upstream data:

 particulatematter/devices/ttgo_mac/up {"app_id":"particulatematter","dev_id":"ttgo_mac","hardware_serial":"000084B14CA4AE30","port":1,"counter":16,"payload_raw":"AAEALAAd/////w==","metadata":{"time":"2019-04-13T08:37:45.338427686Z","frequency":868.3,"modulation":"LORA","data_rate":"SF11BW125","airtime":823296000,"coding_rate":"4/5","gateways":[{"gtw_id":"eui-008000000000b8b6","timestamp":2000599916,"time":"2019-04-13T08:37:45.320735Z","channel":1,"rssi":-115,"snr":-3,"rf_chain":1,"latitude":52.0182,"longitude":4.70844,"altitude":27}]}}

Example downstream data:

 particulatematter/devices/ttgo_mac/events/down/sent {"payload":"YPUvASalGgEDEf8AAcqtmOw=","message":{"app_id":"particulatematter","dev_id":"ttgo_mac","port":0},"gateway_id":"eui-008000000000b8b6","config":{"modulation":"LORA","data_rate":"SF9BW125","airtime":164864000,"counter":282,"frequency":869525000,"power":27}}

Gateway API:

 https://account.thethingsnetwork.org/api/v2/gateways/eui-xxxxxxxxxxx

Useful tools: